Design
Illustration of the pressure control panel with gas cylinder connected
Pos. | Designation | Short name | Connection |
1 | Process gas source valve |
|
|
2 | Cylinder connection incl. plug |
| Cylinder connection |
3 | High-pressure process gas shut-off valve | HPI |
|
4 | Pressure regulator | PR |
|
5 | Pre-pressure gauge | PG P1 |
|
6 | Outlet pressure gauge | PG P2 |
|
7 | Process line isolation on low pressure side | PLI |
|
8 | High-pressure waste gas valve | HPV |
|
9 | Non-return valve on relief valve | NRV3 |
|
10 | Service valve | S |
|
11 | High pressure safety stop with marking | SP300 | Compression ring fitting 6x1 mm |
12 | Grub screw |
|
|
NOTICE
The SP300 operates fully automatically with internal auxiliary energy, which is extracted from the process gas. No manual triggering option is provided.
NOTICE
The complete triggering is indicated by a part of the closing piston with o-ring protruding from the SP300. If only part of the closing piston is visible and the o-ring is not visible, partial triggering is carried out. This situation represents a defect in the SP300. It must be corrected in accordance with "Resetting the SP300".