Design

Diagram of the FS1A8P controller

Position

Designation

1

Emergency stop

2

Red LED

3

Yellow LED

4

Green LED

5

Main switch

6

Pneumatic input

7

Pneumatic outputs

 

The complete enclosure assembly has an environmental rating of IP65. On the front is an emergency stop button [1] and on the rear there is an on/off switch [5]. Internally there is an additional input for an external emergency stop. This can be deactivated as necessary. When one of the two shutdown options is activated, all valves are closed and the power supply to the solenoid valves is interrupted.

The controller power supply is provided via a three-wire mains cable. The FS1A8P controller is supplied with a 5 m long, permanently wired cable that can be cut to the desired length. The controller is secured internally with a circuit breaker of characteristic B.

Diagram of the FS1A8P controller

Position

Description

1

8 fuses for analogue inputs

2

Main fuse

3

Circuit breaker

4

External emergency shut-off input

5

0V connection

6

7 Digital inputs

7

7 Digital Outputs

8

8 Analogue inputs

9

24V connection