Troubleshooting and fault rectification
Fault  | Possible cause  | Remedy  | 
Outlet pressure too low  | Process gas source empty  | Check inlet pressure on the pressure regulator and change the process gas source if necessary  | 
Vibration noises in the pressure regulator  | Pressure regulator faulty  | Replace pressure regulator  | 
Pressure regulator frozen  | Flow rate too high  | Reduce flow rate or use gas preheater if possible  | 
System pressure cannot be set to the desired value  | Pressure regulator faulty  | Replace pressure regulator  | 
System pressure outside the intended system pressure  | Only operate the system at the intended range 
  | |
Flow insufficient or fluctuating  | Inlet pressure of the process gas too low  | Increase inlet pressure  | 
Valve faulty  | Replace faulty valve  | |
Filter loaded  | Change filter  | |
Relief valve, over-pressure valve, safety valve or burst disc are discharging gas  | Impermissible pressure rise in the outlet pressure range  | Close all valves and check pressure control panel  | 
HPI valve cannot be opened or closed  | Pneumatic pressure too low  | Check pneumatic pressure  | 
Compressed air hose ripped  | Replace compressed air hose out  | |
Leak  | Connection leaking  | Flush pressure control panel clear and perform pressure test and leak test  |