Design

Illustration of the pressure control panel with gas cylinder connected

Pressure control panel design BE56-2-VCR

Pos.

Designation

Short name

Connection

1

Process gas source valve

 

 

2

Cylinder connection incl. plug

 

Cylinder connection
(see label)

3

High-pressure process gas shut-off valve

HPI

 

4

Pre-pressure gauge

PG P1

 

5

High-pressure waste gas valve

HPV

 

6

Pressure regulator

PR

 

7

Outlet pressure gauge

PG P2

 

9

Waste gas connection

 

¼"-VCR female

10

Process gas connection

 

¼"-VCR female

11

Waste gas connection (burst disc)

 

¼" pipe

12

Label